CUBIC CM1106 Single Beam NDIR CO2 Sensor Module

The cm1106 sensor platform allows you to use CM1106 CO2 sensors with ESPHome.

CUBIC CM1106 Single Beam NDIR CO2 Sensor Module.

Communication with the CM1106 sensor is done via UART, so you need to define a UART bus in your configuration. Connect the rx_pin to the TX pin of the CM1106 and the tx_pin to the RX pin of the CM1106 (note that the TX/RX labels are from the sensor’s perspective). Additionally, set the baud rate to 9600 for proper communication.

# Example configuration entry
sensor:
- platform: cm1106
co2:
name: CM1106 CO2 Value
  • co2 (Optional): The CO2 data from the sensor in parts per million (ppm). All options from Sensor.

  • update_interval (Optional, Time): The interval to check the sensor. Defaults to 60s.

  • uart_id (Optional, ID): Manually specify the ID of the UART Component if you want to use multiple UART buses.

  • id (Optional, ID): Manually specify the ID used for actions.

  • automatic_baseline_calibration (Optional, boolean or mapping): CM1106 has an automatic baseline calibration procedure (ABC). The sensor refreshes the baseline against the lowest reading observed during each calibration cycle; with the default settings a cycle starts 24 hours after the sensor is powered on and then repeats every 15 days. Set this value to false to disable ABC on boot. ABC assumes the sensor sees outdoor air (about 400ppm) at some point in every cycle; a room that stays occupied or poorly ventilated never does, so the baseline drifts and readings end up too low. Disabling it is the safer choice for most indoor sensors. Set this value to true to enable ABC on boot. No calibration command is sent if not set (the sensor’s stored logic is used).

    • cycle (Optional, int, [1, 90]): Calibration cycle interval in days. Defaults to 15.
    • baseline (Optional, int, [400, 10000]): The reference concentration the baseline is refreshed against, in ppm. Defaults to 400.

    Set to true to enable ABC on boot with the default cycle and baseline:

    automatic_baseline_calibration: true

    Alternatively, provide a mapping to customize the cycle and baseline; the mapping implicitly enables ABC:

    automatic_baseline_calibration:
    cycle: 7
    baseline: 420

This action executes zero point calibration command on the sensor with the given ID.

To perform zero-point calibration, the CM1106 sensor must operate in a stable 400ppm CO₂ environment for at least 20 minutes before executing this function.

on_...:
then:
- cm1106.calibrate_zero: my_cm1106_id

You can provide an action to perform from Home Assistant

api:
actions:
- action: cm1106_calibrate_zero
then:
- cm1106.calibrate_zero: my_cm1106_id

Examples:

Button to start the calibration process:

button:
- platform: template
name: "CM1106 Calibration"
entity_category: diagnostic
on_press:
then:
- cm1106.calibrate_zero: my_cm1106_id

Pseudo-automatic calibration by CO2 value:

binary_sensor:
- platform: template
id: co2_calibration
lambda: |-
if (id(co2sensor).get_state() < 400) {
return true;
} else {
return false;
}
filters:
- delayed_on: 15min
on_press:
then:
- cm1106.calibrate_zero: my_cm1106_id
internal: true

This action enables automatic baseline calibration on the sensor with the given ID.

on_...:
then:
- cm1106.abc_enable: my_cm1106_id

This action disables automatic baseline calibration on the sensor with the given ID.

on_...:
then:
- cm1106.abc_disable: my_cm1106_id

You can provide a switch to control ABC from Home Assistant. restore_mode: DISABLED keeps the switch from sending a command at boot, so the automatic_baseline_calibration setting above stays in charge of the boot state.

switch:
- platform: template
name: "CM1106 ABC"
optimistic: true
restore_mode: DISABLED
on_turn_on:
cm1106.abc_enable: my_cm1106_id
on_turn_off:
cm1106.abc_disable: my_cm1106_id