DeltaSol BS Plus VBus Guide
The deltasol_bs_plus RX decoder receives broadcasts from the DeltaSol BS Plus. Use the VBus hardware
guide and configure the UART first.
Receive Telemetry
Section titled “Receive Telemetry”vbus: uart_id: resol
sensor: - platform: vbus model: deltasol_bs_plus temperature_1: name: Solar Temperature 1Each field below is optional. Add only the measurements you need and name them for the controller terminals and hydraulic scheme in your installation. These are broadcast values; adding them does not poll settings.
Available Sensors
Section titled “Available Sensors”- Temperature 1:
temperature_1. - Temperature 2:
temperature_2. - Temperature 3:
temperature_3. - Temperature 4:
temperature_4. - Pump speed 1:
pump_speed_1. - Pump speed 2:
pump_speed_2. - Operating hours 1:
operating_hours_1. - Operating hours 2:
operating_hours_2. - Heat quantity:
heat_quantity. - Time:
time. - Version:
version.
All fields support the normal Sensor options.
Status And Fault Sensors
Section titled “Status And Fault Sensors”- Relay 1 on:
relay1. - Relay 2 on:
relay2. - Sensor 1 fault:
sensor1_error. - Sensor 2 fault:
sensor2_error. - Sensor 3 fault:
sensor3_error. - Sensor 4 fault:
sensor4_error. - Collector maximum option:
collector_max. - Collector minimum option:
collector_min. - Collector frost protection option:
collector_frost. - Tube collector option:
tube_collector. - Recooling option:
recooling. - Heat quantity measurement option:
hqm.
Add these under binary_sensor: with platform: vbus, the same model and a name for each desired field.
See the binary sensor example and Binary Sensor options.
Protocol Reference
Section titled “Protocol Reference”The broadcast source address is 0x4221. Use it for controller
identification
or documented custom decoding; ordinary deltasol_bs_plus RX sensors do not need an explicit address.