DeltaSol C VBus Guide

The deltasol_c RX decoder receives broadcasts from the DeltaSol C. Use the VBus hardware guide and configure the UART first.

vbus:
uart_id: resol
sensor:
- platform: vbus
model: deltasol_c
temperature_1:
name: Solar Temperature 1

Each field below is optional. Add only the measurements you need and name them for the controller terminals and hydraulic scheme in your installation. These are broadcast values; adding them does not poll settings.

  • Temperature 1: temperature_1.
  • Temperature 2: temperature_2.
  • Temperature 3: temperature_3.
  • Temperature 4: temperature_4.
  • Pump speed 1: pump_speed_1.
  • Pump speed 2: pump_speed_2.
  • Operating hours 1: operating_hours_1.
  • Operating hours 2: operating_hours_2.
  • Heat quantity: heat_quantity.
  • Time: time.

All fields support the normal Sensor options.

  • Sensor 1 fault: sensor1_error.
  • Sensor 2 fault: sensor2_error.
  • Sensor 3 fault: sensor3_error.
  • Sensor 4 fault: sensor4_error.

Add these under binary_sensor: with platform: vbus, the same model and a name for each desired field. See the binary sensor example and Binary Sensor options.

The broadcast source address is 0x4212. Use it for controller identification or documented custom decoding; ordinary deltasol_c RX sensors do not need an explicit address.